Files to download
TERMET APLA
A
TERMET APLA is an energy-efficient and eco-friendly solution that ensures high thermal comfort. Thanks to advanced technology, it recovers heat from exhaust gases, reducing heating bills. Quiet operation, a compact design, and intuitive controls make it the perfect choice for any home.
One of the boiler's main advantages is its compact size, making it ideal for installation in small and cramped spaces. It can also be used in existing installations where retrofitting to a new heat source is difficult due to existing constraints.
One of the boiler's main advantages is its compact size, making it ideal for installation in small and cramped spaces. It can also be used in existing installations where retrofitting to a new heat source is difficult due to existing constraints.
- Energy class: A
- Internet control - room temperature management via smartphone or tablet using the Termet Comfort System package
- Use of the latest generation stainless steel heat exchanger with a single coil
- Exceptionally wide power modulation range: from 15% to 100%
- Compact unit dimensions
- Highly efficient circulation pump
- Fan with variable speed control (electronically controlled)
- Stainless steel cylindrical burner with low NOx emissions (class 6)
- Complete security system
- Open-Therm communication system, e.g., using the CR11011 controller
- Compatible with multi-zone modules for heating systems
- Compatible with air-to-water heat pumps
- Connection of a domestic hot water cylinder thanks to the built-in three-way valve (the NTC cylinder sensor must be purchased separately)
| Parameters | Value |
| Thermal power (at temp. 80/60°C) | 3,5 - 19,4 kW |
| Thermal power (at temp. 50/30°C) | 3,9 - 21,4 kW |
| Heat load | 3,6 - 20,0 kW |
| Seasonal space heating energy efficiency ηs | 94,0 % |
| Efficiency of the boiler at nominal load and average boiler water temperature of 70°C |
97,0 % |
| Efficiency of the boiler at partial load and return water temperature of 30°C |
107,0 % |
| Seasonal space heating energy efficiency class | A |
| Useful heat output at rated thermal power P4 (for modulated boilers - arithmetic mean of min and max) |
19,5 kW |
| Useful heat output at 30% of rated power P1 (for modulated boilers - 30% of arithmetic mean) |
6,5 kW |
| Efficiency η4 | 89,9 % |
| Efficiency η1 | 99,4 % |
| Max water pressure | 3 bar |
| Max CH temperature | 95 °C |
| Standard adjustable temperature | 35 - 80 °C |
| Reduced adjustable temperature | 27 - 55 °C |
| Pump head at 0 flow | 0,7 bar |
| Range of water temperature regulation | 30 - 60 °C |
| Sound power level LWA | 48,0 dB |
| Emission of nitrogen dioxide | 26,0 mg/kWh |
| Emission class of nitrogen dioxide (NOx) | 6 |
| Expansion vessel capacity | 8 dm³ |
| Standby mode power consumption PSB | 0,001 kW |
| Electricity consumption at full load elmax | 0,070 kW |
| Electricity consumption at partial load elmax | 0,057 kW |
| Type and supply voltage | ~ 230 ±10%/ 50Hz V |
| Protection degree | IPX4D |
| Heating water and gas connection | G 3/4 inch |
| Dimensions | 650 x 400 x 303 mm |
| Weight | 30,0 kg |
| Exchanger material | INOX steel |
| Parameters | Value |
| Thermal power (at temp. 80/60°C) | 3,5 - 23,3 kW |
| Thermal power (at temp. 50/30°C) | 3,9 - 25,7 kW |
| Heat load | 3,6 - 24,0 kW |
| Seasonal space heating energy efficiency ηs | 94,0 % |
| Efficiency of the boiler at nominal load and average boiler water temperature of 70°C |
97,0 % |
| Efficiency of the boiler at partial load and return water temperature of 30°C |
107,0 % |
| Seasonal space heating energy efficiency class | A |
| Useful heat output at rated thermal power P4 (for modulated boilers - arithmetic mean of min and max) |
23,5 kW |
| Useful heat output at 30% of rated power P1 (for modulated boilers - 30% of arithmetic mean) |
7,8 kW |
| Efficiency η4 | 88,9 % |
| Efficiency η1 | 98,6 % |
| Max water pressure | 3 bar |
| Max CH temperature | 95 °C |
| Standard adjustable temperature | 35 - 80 °C |
| Reduced adjustable temperature | 27 - 55 °C |
| Pump head at 0 flow | 0,7 bar |
| Range of water temperature regulation | 30 - 60 °C |
| Sound power level LWA | 49,0 dB |
| Emission of nitrogen dioxide | 29,0 mg/kWh |
| Emission class of nitrogen dioxide (NOx) | 6 |
| Expansion vessel capacity | 8 dm³ |
| Standby mode power consumption PSB | 0,002 kW |
| Electricity consumption at full load elmax | 0,093 kW |
| Electricity consumption at partial load elmax | 0,062 kW |
| Type and supply voltage | ~ 230 ±10%/ 50Hz V |
| Protection degree | IPX4D |
| Heating water and gas connection | G 3/4 inch |
| Dimensions | 650 x 400 x 303 mm |
| Weight | 30,0 kg |
| Exchanger material | INOX steel |
The manufacturer reserves the right to change the device’s structure which do not have a significant impact on functional and technical characteristics of a product.